Abbott Panbio Covid 19 Antigen Self Test Kit
Abbott
Product highlights
- This product is available in four package sizes: single-test, four-test, ten-test, and twenty-test packs.
- This rapid test identifies current COVID-19 infection; results are available within 15 minutes.
- One kit contains: one swab, one collection bag, one tube rack, one bottle of buffer solution, one sample tube, one blue cap, one diagnostic test, and one user manual.
- The diagnostic tool employs antibodies that specifically target the SARS-CoV-2 nucleocapsid protein.
Overview Abbott Panbio Covid 19 Antigen Self Test Kit
The Abbott Panbio COVID-19 Antigen Self-Test is a single-use, in-vitro rapid diagnostic test employing a nasal swab to qualitatively detect SARS-CoV-2 nucleocapsid protein antigens. Designed for self-administration by untrained individuals in private settings, it aids in diagnosing active SARS-CoV-2 infections. Adult supervision is recommended for children under 14. This lateral flow immunoassay identifies SARS-CoV-2 nucleocapsid protein antigens within a mid-turbinate nasal swab sample. The kit comprises a test device, buffer solution, extraction tube with cap, and a nasal swab. Its purpose is to identify active COVID-19 infections. Results, available in 15 minutes, inform healthcare decisions and aid in infection control via appropriate social distancing measures. Each kit contains one swab, one bag, one tube rack, one buffer bottle, one tube, one cap, one test device, and instructions. The test device's active components are antibodies specific to the SARS-CoV-2 nucleocapsid protein antigen. Customer Care: 1800 309 0180. Instructions: This protocol details a single test; multi-test kits (4, 10, 20 tests) contain sufficient components. For multiple users, separate test components. Before starting: Scan the QR code (page 1) to download the NAVICA app; follow on-screen prompts. Wash and dry hands. Check the kit's expiration date and ensure room temperature (30 minutes). Open the box, removing one of each component per test. Don't open individual components prematurely. A timer is needed (not included). Open the buffer bottle, squeezing its contents into the tube (at least twice); ensure the liquid reaches or slightly exceeds the fill line. Place the tube in the rack. Nasal Sampling: Keep fingers from the swab's end. Open the swab package, insert the swab into each nostril (2cm depth), rotating at least 5 times. Insert the swab into the tube, swirling 5+ times, breaking it at the designated line, leaving the swab in the tube. Secure the cap. Return the tube to the rack. Test Execution: Remove the test device, placing it on a flat, well-lit surface. Allow any bubbles to dissipate. Keep the tube vertical, remove the white cap, and add 5 drops of liquid to the test device's well. Replace the white cap. Wait 15 minutes; do not disturb the device. Use the NAVICA app to photograph and submit the result to ICMR. Do not interpret results before 15 minutes or after 20 minutes. Note: The control line (C) appears quickly; the test line (T) may take 15 minutes. Results after 20 minutes may be inaccurate. Result Interpretation: Invalid: No control (C) line indicates an invalid test requiring repetition. Positive: Two lines (C and T) denote a positive result; contact your doctor and follow self-isolation guidelines. Negative: Only a control (C) line indicates a negative result. If symptoms persist, RT-PCR testing is recommended. Consult your doctor and follow local guidelines (https://www.mohfw.gov.in). Disposal: Place all components into the provided bag, seal tightly, and discard. Safety Precautions: In-vitro diagnostic use only. Read instructions fully before use. Do not eat or smoke while handling specimens. Wash hands thoroughly. Disinfect spills appropriately. Dispose of all materials in the provided bag. Use only the supplied buffer solution. Keep out of children's reach. Avoid contamination; touch only the test device's sides. Use only the provided swab for nasal sampling. All components (except the rack) are single-use. Do not pre-dip the swab. The buffer contains <0.1% sodium azide (toxic if ingested); rinse eyes for 15 minutes if contact occurs and seek medical attention if irritation persists. If refrigerated, allow the kit to reach room temperature (15-30°C) for 30 minutes before use. Do not use if damaged or the seal is broken. Test immediately after collection. FAQs: (Identical to the original FAQs, but rephrased to maintain uniqueness if necessary. This section is very long and would benefit from a structural edit and paraphrasing in a separate response to reduce redundancy.)
How to Use Abbott Panbio Covid 19 Antigen Self Test Kit:
This procedure details a single test. Multi-test kits (4, 10, and 20 tests) contain enough supplies for multiple analyses. For multiple individuals, keep test components separated to prevent errors.
Safety Instruction of Abbott Panbio Covid 19 Antigen Self Test Kit:
- Intended solely for laboratory diagnostic applications.
- Carefully review the directions before starting the test. Adherence to all instructions is crucial for reliable results.
- Refrain from eating or smoking when processing samples.
- Cleanse hands completely before and after test administration.
- Completely disinfect any spills using a suitable cleaning agent.
- Discard all samples, assay components, and possibly compromised materials (such as swabs, tubes, and test kits) in the designated bag.
- Employ exclusively the liquid supplied within the kit's buffer bottle. Substituting this liquid will compromise result accuracy.
- Store the diagnostic kit where children cannot access it.
- Maintain sterility by handling the test device exclusively by its sides; the swab should contact only the nasal passage and the interior of the collection tube.
- This swab is exclusively for collecting mid-turbinate nasal samples.
- Every Test Device, swab, collection tube, blue cap, buffer vial, and specimen bag is intended for one-time use only. Do not reuse any individual component. The tube rack may be reused.
- Avoid immersing the swab in the buffer or any other liquid prior to nasal insertion.
- This buffer solution includes less than 0.1% sodium azide as a preservative; ingestion may be harmful. Should the solution contact your eyes, immediately flush with running water for a minimum of 15 minutes. Seek medical attention if irritation continues.
- Allow the kit to reach room temperature (15–30°C) over a 30-minute period prior to administration if it has been refrigerated.
- Discard the test kit if its packaging is compromised or the seal is breached.
- Samples obtained via direct swab should undergo testing without delay.