Search Icon

AUM Pharmacy

Hi there!

Hello, Login
All Categories
VisaVisaVisa
slide-0
slide-1
slide-2
slide-3
slide-4
slide-5
slide-6
slide-7
slide-8
slide-9
slide-10

FreeStyle Combo Pack of Libre Sensor, Libre Reader and Optium Blood Glucose 50 Test Strip

Abbott,Abbott Healthcare Private Limited

Product highlights

  • This package includes a Libre sensor, a Libre reader, and blood glucose test strips.
  • Simple and safe to administer.
  • This aids in tracking blood sugar and ketone concentrations.

Overview FreeStyle Combo Pack of Libre Sensor, Libre Reader and Optium Blood Glucose 50 Test Strip

Abbott FreeStyle Optium Blood Glucose Test Strips are individually foil-wrapped, employing Germiguard protection for hygienic, rapid blood absorption during glucose monitoring. These strips facilitate diabetes management and attainment of target blood sugar levels via self-testing. **Specifications & Features:** * Complies with ISO 15197:2013 standards. * Requires no coding. * Individually foil-wrapped with Germiguard protection. * Designed for swift, simple, and secure blood glucose testing. **Instructions:** Use exclusively with the FreeStyle Optium meter. Apply a blood droplet to the strip's tip for meter readings. **Safety Precautions:** Use immediately after foil packet opening. Store between 4℃-30℃ (39ºF-86ºF); improper storage may yield inaccurate results. Avoid direct sunlight and heat. Use each strip once and discard. Do not use expired, wet, bent, scratched, or damaged strips; nor strips with punctured/torn foil. Exercise caution around children due to small parts posing a choking risk. Always read the label fully before use. Store in a cool, dry, dark area, out of children's reach. Data on file: Abbott Diabetes Care. The Abbott FreeStyle Libre System Reader, paired with a FreeStyle Libre Sensor, measures interstitial fluid glucose levels in individuals (age 4+) with diabetes, including pregnant women. It's intended to replace finger-prick testing in diabetes self-management, including insulin dosing. Discreet glucose monitoring avoids the disruption of routine finger pricks. **Uses:** Monitors glucose and ketone levels. **Specifications & Features:** * One-second glucose readings. * Displays current glucose, 8-hour history, and trend arrows. * Stores 90 days of glucose data. * Continuous glucose tracking for pattern identification. * Measures blood glucose and ketone levels (via test strip port). **Instructions:** Activate the reader; set language, date, time, and target glucose range. Scan the sensor (applied to the upper arm) for glucose levels and trend arrows. **Warnings:** Don't ignore symptoms of high/low blood glucose. If readings seem inaccurate or inconsistent with symptoms, verify with a fingerstick test and consult your healthcare provider. (For children aged 4-17: adult supervision required for reader/sensor use and data interpretation). **Safety Precautions:** Contains small parts – choking hazard. Avoid contaminating the reader's USB and test strip ports. Interstitial fluid/capillary blood glucose differences may occur, particularly during rapid blood glucose changes. Not re-sterilizable; further irradiation may affect accuracy. The Abbott FreeStyle Libre Sensor is a cutting-edge glucose monitoring system eliminating routine finger-prick testing. It offers accurate, painless, and user-friendly glucose level monitoring with trend arrow indicators. **Uses:** Measures body glucose levels. **Specifications & Features:** * Water-resistant (1 meter, 30 minutes). * Protected against objects >12mm (IP27). * Trend arrow indicates glucose level changes. **Instructions:** Select a flat, clean upper arm site (at least 2.5cm from injection sites). Apply the sensor using the applicator. Scan with the reader for readings. Cleanse the injection site with the provided alcohol swab. **Warnings:** Don't ignore symptoms of high/low blood glucose. Verify readings if inaccurate or inconsistent with symptoms using a fingerstick test; consult your healthcare provider. **Safety Precautions:** Sterile unless opened or damaged. Store between 4°C-25°C (do not freeze). Do not use if expired. Avoid swallowing small parts. Keep away from children and eyes. Rinse with water if swab contacts eyes. Discontinue use if skin irritation occurs. Single-use only. Remove sensor before MRI. Standard ascorbic acid doses are acceptable; however higher doses may affect accuracy. Alcohol swab label: reliject pre-injection swab; 1 swab; for skin cleansing prior to injection; saturated with 70% Isopropyl Alcohol.

How to Use FreeStyle Combo Pack of Libre Sensor, Libre Reader and Optium Blood Glucose 50 Test Strip:

Identify a flat, stable skin area on your upper arm's back, avoiding areas with moles, scars, or tattoos, and at least 2.5cm (1 inch) from any insulin injection site. For optimal comfort, choose a location different from your previous application site. Cleanse the selected area with soap and ensure complete dryness before sensor placement. Fully remove the sensor's protective lid. Detach and retain the applicator cap. Align the sensor's dark marking with its applicator counterpart. Press firmly onto a stable surface until the applicator stops. Securely attach the sensor to your prepared skin area, then gently remove the applicator. Your glucose levels will be displayed after scanning the sensor with your reader.

Safety Instruction of FreeStyle Combo Pack of Libre Sensor, Libre Reader and Optium Blood Glucose 50 Test Strip:

  • The sensor package maintains sterility until opened or compromised.
  • Maintain the sensor kit within a temperature range of 4°C to 25°C. Refrigeration is optional, provided the refrigerator's temperature remains within this same 4°C to 25°C range.
  • Avoid freezing. Discard if past the expiration date.
  • Interference Considerations: Routine doses of vitamin C (ascorbic acid) do not interfere with sensor operation. However, exceeding the recommended daily intake of ascorbic acid can lead to falsely elevated sensor readings.
  • The pre-injection cleansing swab is identified as "Reliject."
  • One specimen collected via swab.
  • Cleanse the skin before administering the injection.
  • Contains 70% isopropyl alcohol.
  • The FreeStyle Libre flash glucose monitoring system comprises small components posing a potential ingestion hazard.
  • Store out of reach of children.
  • Avoid contact with eyes.
  • Following contact with a swab, rinse the affected area with water.
  • Stop using the product if a skin rash or irritation develops.
  • Discard after the expiration date.
  • Discard after use.
  • Magnetic Resonance Imaging (MRI) necessitates sensor removal beforehand.

Prescription Icon

Rate your recent purchases

Your ratings and reviews help lakhs of people purchase the right product.

Ratings & Reviews

0

Ratings 0 Reviews

5
0.0%
4
0.0%
3
0.0%
2
0.0%
1
0.0%
FreeStyle Combo Pack of L...
11,135
MRP 12,573
11% off