- Track your glucose levels effortlessly using the FreeStyle LibreLink app on your smartphone.
- The FreeStyle Libre Sensor, applied with the provided single-use applicator, adheres comfortably to the upper arm for a period of up to two weeks.
- The FreeStyle Libre Sensor is waterproof and durable enough for showering, swimming, bathing, and exercise, integrating effortlessly into daily routines.
- The FreeStyle Libre Sensor is shower, swim, bath, and exercise compatible, integrating effortlessly into daily life.
- The FreeStyle Libre system delivers precise, reliable glucose readings consistently for two weeks, eliminating the requirement for finger-stick calibration.
- This sensor offers water resistance to a depth of one meter (three feet) for a maximum submersion time of 30 minutes.
Overview FreeStyle Libre System - Sensor | Diabetes Monitoring Devices | Blood Glucose Monitors
The FreeStyle Libre System is an innovative glucose monitoring system employing a sensor to eliminate the need for frequent finger-prick blood tests in diabetic patients. This accurate, painless, and user-friendly system provides real-time glucose level readings with a trend arrow indicating whether levels are rising, falling, or stable. Its application involves: measuring glucose levels; a sensor waterproof to one meter for 30 minutes (IP27 rating); and a trend indicator showing glucose level changes. Application instructions: select a flat, clean area on the upper arm (at least 2.5cm from insulin injection sites, avoiding moles, scars, or tattoos); prepare the site with soap and water; peel open the sensor package; firmly attach the sensor using the applicator; activate via the FreeStyle LibreLink app (compatibility details available online); and register with LibreView if using the app. The included alcohol swab (reliject pre-injection swab, 70% isopropyl alcohol) should be used for skin cleansing before injection. External use only; single-use only; discard after use. Do not use to sterilize invasive medical devices. Always verify readings with a finger-stick test if symptoms don't align with sensor data or accuracy is questionable. Consult a healthcare professional for any discrepancies. Store the sensor between 4°C and 25°C; do not freeze; discard after expiry. Standard vitamin C doses have minimal impact, but excessive intake may elevate readings. The system contains small parts; keep away from children and eyes. Rinse with water if contact occurs; discontinue use if irritation develops; do not reuse; and remove the sensor before MRI scans.
How to Use FreeStyle Libre System - Sensor | Diabetes Monitoring Devices | Blood Glucose Monitors:
Identify a flat, stable skin area on your upper arm's back, unaffected by daily movement (avoid bending or flexing). Exclude regions with moles, scars, or tattoos, and ensure at least a 2.5cm (1-inch) margin from any insulin injection point. For optimal comfort and to minimize irritation, rotate application sites, avoiding recently used areas. Cleanse the selected spot with soap and let it air dry completely before sensor placement. Fully peel open the sensor package. Remove and retain the sensor applicator cap. Align the applicator's dark indicator with the package's matching mark. Press firmly onto the applicator until it clicks, using a solid surface. Position the applicator on the prepared skin area and press down securely to attach the sensor. Carefully detach the applicator. The sensor should adhere to your skin. Initiate sensor activation through the FreeStyle LibreLink app. Note that app compatibility is limited to specific mobile devices and operating systems; consult the manufacturer's website for compatible devices prior to use. FreeStyle LibreLink usage may necessitate registration with LibreView.
Safety Instruction of FreeStyle Libre System - Sensor | Diabetes Monitoring Devices | Blood Glucose Monitors:
- The sensor package maintains sterility until its integrity is compromised.
- The sensor kit should be stored in a location with a temperature between 4°C and 25°C. Refrigeration is permissible, provided the refrigerator maintains a temperature within this range.
- Avoid freezing. Discard after the expiration date.
- Interference Factors: Usual doses of vitamin C (ascorbic acid) do not affect sensor readings. However, exceeding the recommended daily intake of ascorbic acid can lead to falsely elevated sensor measurements.
- The antiseptic wipe bears the product identifier: reliject pre-injection swab.
- One specimen collection
- Cleanse the skin before administering the injection.
- Contains 70% isopropyl alcohol.
- The FreeStyle Libre flash glucose monitoring device comprises small components posing a potential ingestion hazard.
- Store out of reach of children.
- Avoid contact with eyes.
- Rinse with water if a swab touches the area.
- Stop using the product if a skin rash or irritation develops.
- Discard after the expiration date.
- Discard after use.
- Magnetic Resonance Imaging (MRI) requires sensor removal beforehand.